ISSN: 2536-7099
Model: Open Access/Peer Reviewed
DOI: 10.31248/JASVM
Start Year: 2016
Email: jasvm@integrityresjournals.org
https://doi.org/10.31248/JASVM2025.689 | Article Number: 3750FC758 | Vol.11 (5) - October 2026
Received Date: 13 September 2026 | Accepted Date: 26 October 2026 | Published Date: 30 October 2026
Authors: Sulaiman A.* , Bappah M. N. , Abdurrahman M. and Lawal M.
Keywords: Haematological parameters, Exposure duration, diagnostic ultrasound, bioeffects, New Zealand White rabbits.
Diagnostic ultrasound examinations are becoming longer and more frequent, yet the effect of scanning duration on circulating blood is poorly defined. This exploratory study examined how the duration of uninterrupted diagnostic brightness-mode scanning over the femoral region affects blood cell parameters in New Zealand White rabbits. Twelve male rabbits were allocated to four groups of three: a control group handled for 30 minutes with the scanner switched off, and groups scanned for 10, 20 or 30 minutes daily for five consecutive days. Blood was collected at baseline and immediately after each session, and red cell, platelet and white cell indices were analysed by repeated-measures analysis of variance with comparisons against the control. Packed cell volume, haemoglobin concentration and red blood cell count were lower after exposure, most clearly in the 30-minute group (packed cell volume 30.61 ± 3.45% versus 35.89 ± 0.70% in controls). Group differences were not significant, but the day and group-by-day effects were, and the 30-minute group fell significantly below its baseline from day 3 to day 5, with a less consistent decline at 20 minutes and no sustained change at 10 minutes. Monocyte counts were higher after 30 minutes than in controls (0.42 versus 0.10 × 10³/µl; p = 0.003). Platelet counts were lower in the 30-minute group than in controls (p = 0.030), but counts rose above baseline in every group and the difference reflected high control values. Lymphocyte and eosinophil differences occurred only at 20 minutes and were not graded. Other indices did not change meaningfully. Scanning for 30 minutes, beyond a routine examination, was therefore associated with progressive declines in red cell indices and higher monocyte counts. Restraint stress cannot be excluded as a contributor, and acoustic output was not measured, so larger controlled studies are needed.
| American Institute of Ultrasound in Medicine. (2023). AIUM official statement for the statement on biological effects of therapeutic ultrasound. Journal of Ultrasound in Medicine, 42(12), E68-E73. https://doi.org/10.1002/jum.16315 |
||||
| Bachu, V. S., Kedda, J., Suk, I., Green, J. J., & Tyler, B. (2021). High-intensity focused ultrasound: A review of mechanisms and clinical applications. Annals of Biomedical Engineering, 49(9), 1975-1991. https://doi.org/10.1007/s10439-021-02833-9 |
||||
| Bader, K. B., Padilla, F., Haworth, K. J., Ellens, N., Dalecki, D., Miller, D. L., Wear, K. A., & Bioeffects Committee of the American Institute of Ultrasound in Medicine. (2025). Overview of therapeutic ultrasound applications and safety considerations: 2024 update. Journal of Ultrasound in Medicine, 44(3), 381-433. https://doi.org/10.1002/jum.16611 |
||||
| Bain, B. J., & Leach, M. (2025). Blood cells: A practical guide (7th ed.). Wiley. https://doi.org/10.1002/9781394332083 |
||||
| Chmurska-Gąsowska, M., Bojarski, B., & Szała, L. (2021). Haematological changes in rabbits (Oryctolagus cuniculus f. domesticus) in the course of pregnancy. Animal Reproduction, 18(2), e20210013. https://doi.org/10.1590/1984-3143-ar2021-0013 |
||||
| Didkowska, A., Klich, D., Anusz, K., Wojciechowska, M., Kloch, M., Perlińska-Teresiak, M., Bielecki, W., & Olech, W. (2024). Determination of hematological and biochemical values blood parameters for European bison (Bison bonasus). PLOS ONE, 19(5), e0303457. https://doi.org/10.1371/journal.pone.0303457 |
||||
| Han, B., Liu, Y., Zhou, Q., Yu, Y., Liu, X., Guo, Y., Zheng, X., Zhou, M., Yu, H., & Wang, W. (2024). The advance of ultrasound-enabled diagnostics and therapeutics. Journal of Controlled Release, 375, 1-19. https://doi.org/10.1016/j.jconrel.2024.08.039 |
||||
| Idris, S. Y., Lawal, M., Enam, J. S., Muhammed, M. S., Muhammad, Y., & Saleh, A. (2020). Alterations in haematological parameters of multiple in-utero insonated rabbits (Oryctolagus cuniculus). Sokoto Journal of Veterinary Sciences, 18(3), 144-149. https://doi.org/10.4314/sokjvs.v18i3.4 |
||||
| Izadifar, Z., Babyn, P., & Chapman, D. (2017). Mechanical and biological effects of ultrasound: A review of present knowledge. Ultrasound in Medicine & Biology, 43(6), 1085-1104. https://doi.org/10.1016/j.ultrasmedbio.2017.01.023 |
||||
| Liu, T., & Yang, F. (2021). Study on the intervention of platelet biological activity by ultrasound. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, 38(4), 709-715. | ||||
| Luo, D., Chen, W., Wang, W., Chen, J., Xu, H., Chen, J., & Wang, Y. (2021). Low-intensity pulsed ultrasound alleviating myelosuppression of Sprague-Dawley rats after combined treating by paclitaxel and carboplatin. Translational Cancer Research, 10(3), 1181-1190. https://doi.org/10.21037/tcr-20-3035 |
||||
| Martins, J. G., Waller, J., Horgan, R., Kawakita, T., Kanaan, C., Abuhamad, A., & Saade, G. (2024). Point-of-care ultrasound in critical care obstetrics: A scoping review of the current evidence. Journal of Ultrasound in Medicine, 43(5), 951-965. https://doi.org/10.1002/jum.16425 |
||||
| McMahon, D., Jones, R. M., Ramdoyal, R., Zhuang, J. Y. X., Leavitt, D., & Hynynen, K. (2024). Investigation of sonication parameters for large-volume focused ultrasound-mediated blood-brain barrier permeability enhancement using a clinical-prototype hemispherical phased array. Pharmaceutics, 16(10), 1289. https://doi.org/10.3390/pharmaceutics16101289 |
||||
| Mehrpour, M., Shakeri-Zadeh, A., Basir, P., Jamei, B., Ghaheri, H., & Shiran, M. B. (2016). Effects of low-intensity continuous ultrasound on hematological parameters of rats. Journal of Biomedical Physics and Engineering, 6(3), 195-200. | ||||
| Oikonomidis, I. L., Milne, E., & Piccinelli, C. (2021). Differential white blood cell counts in rabbits: A comparison of the Advia 2120 and a manual method. Journal of Veterinary Diagnostic Investigation, 33(4), 670-676. https://doi.org/10.1177/10406387211007877 |
||||
| Plentz, R., Stoffel, P., Kolling, G., Costa, S., Beck, C., & Signori, L. (2008). Hematological changes produced by 1 MHz continuous ultrasound, applied during the acute phase of iatrogenic muscle injury in rats. Brazilian Journal of Physical Therapy, 12(6), 495-501. https://doi.org/10.1590/S1413-35552008005000001 |
||||
| Quarato, C. M. I., Lacedonia, D., Salvemini, M., Tuccari, G., Mastrodonato, G., Villani, R., Fiore, L. A., Scioscia, G., Mirijello, A., Saponara, A., & Sperandeo, M. (2023). A review on biological effects of ultrasounds: Key messages for clinicians. Diagnostics, 13(5), 855. https://doi.org/10.3390/diagnostics13050855 |
||||
| Sidhu, P. S., Ewertsen, C., Piskunowicz, M., Secil, M., Ricci, P., Fischer, T., Gaitini, D., Mitkov, V., Lim, A. K. P., Lu, Q., Chong, W. K., & Clevert, D. A. (2023). Diversity of current ultrasound practice within and outside radiology departments with a vision for 20 years into the future: A position paper of the ESR ultrasound subcommittee. Insights into Imaging, 14, Article 202. https://doi.org/10.1186/s13244-023-01548-w |
||||
| Signori, L. U., da Costa, S. T., Saurin Neto, A. F., Pizzolotto, R. M., Beck, C., Sbruzzi, G., da Silva, A. M. V., & Plentz, R. D. M. (2011). Haematological effect of pulsed ultrasound in acute muscular inflammation in rats. Physiotherapy, 97(2), 163-169. https://doi.org/10.1016/j.physio.2010.06.004 |
||||
| Srivastava, S., Yu, B., Giraud, D., Dighe, M., Dhyani, M., & Barr, R. G. (2026). Overview of diagnostic ultrasound safety: Review for research and institutional review boards. Journal of Ultrasound in Medicine, 45(3), 487-496. https://doi.org/10. 1002/jum.70085 https://doi.org/10.1002/jum.70085 |
||||
| Tan, Y., Guo, Y., Reed-Maldonado, A. B., Li, Z., Lin, G., Xia, S.-J., & Lue, T. F. (2021). Low-intensity pulsed ultrasound stimulates proliferation of stem/progenitor cells: What we need to know to translate basic science research into clinical applications. Asian Journal of Andrology, 23(6), 602-610. https://doi.org/10.4103/aja.aja_25_21 |
||||
| Uddin, S. M. Z., Komatsu, D. E., Motyka, T., & Petterson, S. (2021). Low-intensity continuous ultrasound therapies: A systematic review of current state-of-the-art and future perspectives. Journal of Clinical Medicine, 10(12), 2698. https://doi.org/10.3390/jcm10122698 |
||||
| van Neer, P. L. M. J., Peters, L. C. J. M., Verbeek, R. G. F. A., Peeters, B., de Haas, G., Hörchens, L., Fillinger, L., Schrama, T., Merks-Swolfs, E. J. W., Gijsbertse, K., Saris, A. E. C. M., Mozaffarzadeh, M., Menssen, J. M., de Korte, C. L., van der Steen, J.-L. P. J., Volker, A. W. F., & Gelinck, G. H. (2024). Flexible large-area ultrasound arrays for medical applications made using embossed polymer structures. Nature Communications, 15, Article 2802. https://doi.org/10.1038/s41467-024-47074-1 |
||||
| Wang, W., Chen, J., Luo, D., Chen, J., Xu, H., Chen, W., & Wang, Y. (2021). Effects of low-intensity pulsed ultrasound on myelosuppression of rats induced by chemotherapy drugs with cell cycle specificity. Journal of Ultrasound in Medicine, 40(9), 1811-1822. https://doi.org/10.1002/jum.15562 |
||||
| Witeska, M., Kondera, E., & Bojarski, B. (2023). Hematological and hematopoietic analysis in fish toxicology-A review. Animals, 13(16), 2625. https://doi.org/10.3390/ani13162625 |
||||